Technology and flexibility for managing movements
The RBM84 system can manage global access control.
It is adaptable to the different needs of passageway selection due to the possibility of integration, depending on the requirements requested by the system. The CAME command control unit has dedicated PC software and the related serial interface.
|
|
|
|
 |
|
|
| RBM84 is fully managed by a microprocessor that memorises customer details and allows the connection and control of more sensors and passageways. They are fully independent and can operate with a stable connection to a personal computer at up to 1,000 metres distance. |
|
RBM84 has specific software which allows management of:
- 60 modules of REM expansion
- 128 automations
- 124 command devices
- 128 digital inputs
- 6000 users, in addition to countless other functions. |
|
|
|
|
USER
The RBM84 allows for each user to be associated with a personal registry, an access code (depending also on the system’s control devices), an entrance time and procedure, a status of whether he/she belongs to any user groups, a detailed history record, and many other functions besides.
SYSTEM
The simple and complete software allows for the:
• Management and configuration of all the peripherals installed.
• Association of sensors to given user groups.
• Selection of various anti-passback types.
• Displaying of users found inside the system.
• Control and configuring of the system by modem.
• System’s expansion and modification at any time.
• Management of the “deduction” of credits according to accesses, time bands or time limits.
• Setting of time bands with variable credits.
• Printing of useful information.
• Automatic archiving of the daily movements.
• Limitating cashiers’ power - by alphanumeric passwords - to given operations, which are all recorded in the history file. These are just some of the countless possibilities of the RBM84S control software. |
|
 |
|
|
The REM unit allows the system to expand at any time and to connect other
inputs and outputs such as:
2 x relay contacts
2 x digital inputs
2 x inputs for connection sensors |
|
| Technical Information |
|
Type
|
RBM84
|
PC30
|
REM
|
|
Protection level
|
IP54
|
-
|
IP54
|
|
Power supply
|
230V a.c.
|
24V D.C.
|
230V a.c.
|
| Material |
ABS
|
| Operating temperature |
-20°C min. +70°C max.
|
|
|
|
|
| Maximum connection distances |
The RS232 serial connection cable between personal computer and PC30 is supplied as standard. Below are the maximum cabling distances between the components:
|
|
Personal computer <=> PC30
|
max 1,5 m |
|
PC30 <=> RBM84
|
max 1000 m |
|
RBM84 (profile connection)
|
max 1000 m |
| first REM (with two profile connections) <=> Last of the REMs |
max 1000 m |
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|